Building envelope
The walls, roof, foundation, windows, doors, and other components separating conditioned indoor space from the outdoors.
Resources
Technical context, plain-language definitions, and direct answers to the questions that should come before a performance claim.
Start here
The site separates mechanism, evidence, company context, and partnership needs so readers can assess each without mistaking one type of information for another.
Assembly, heat transfer, operating modes, ICF distinction, and engineering constraints.
Open guideWhat is established, modeled, independently analyzed, and still unmeasured.
Open guideOrigin, founder, intellectual-property context, and the research purpose behind the work.
Open guideTWT is a proposed building-system approach that combines exterior insulation, concrete thermal mass, embedded hydronic tubing, and a conductive room-facing finish. Its purpose is to make the structure part of heating, cooling, and thermal storage.
It describes the proposed wall operating temperature band, not hydronic supply-water temperature. The lower part of the band is relevant to cooling and the upper part to heating; the usable setpoint depends on room conditions, load, and dew point.
No. TWT is designed as an envelope and distribution concept that can be studied with different compatible heat sources. Solar thermal and passive-solar strategies are optional proposed integrations, not prerequisites for the base wall concept.
No. Conventional ICF commonly leaves insulation on both sides of the concrete core. TWT proposes concentrating insulation on the exterior so the concrete mass remains more thermally connected to the room, then adds embedded hydronics as part of the system.
The current record includes established building-science principles, documented founder modeling, and a limited-scope independent wall analysis. Whole-building seasonal performance, controls, costs, and integrated cooling behavior have not yet been field-measured.
A cooler room-facing mass can absorb sensible heat, which is established physics. The eventual cooling capacity and control strategy must be measured, and every cooled surface must remain safely above the room dew point to prevent condensation.
The room-facing finish needs to remain thermally conductive enough to preserve exchange between the concrete mass and the room. Final finish specifications need to be confirmed through engineering and prototype testing.
TWT is seeking researchers, engineering teams, testing facilities, industry collaborators, and funding partners who can help define methods, test assemblies, instrument a prototype, and publish transparent results.
Glossary
A compact reference for terms used across TWT materials. Definitions explain the concept; they are not system-performance claims.
The walls, roof, foundation, windows, doors, and other components separating conditioned indoor space from the outdoors.
A heat-pump efficiency ratio: useful heating or cooling delivered divided by electrical energy used. Actual values depend on equipment and operating conditions.
The temperature at which air reaches saturation and moisture condenses. Cooled radiant surfaces must stay above it with a suitable safety margin.
An uninterrupted insulation layer placed outside the structural mass to reduce thermal bridging and outward heat flow.
Heating or cooling distribution that uses water or a water-glycol mixture circulating through tubing.
A construction system that uses permanent foam forms filled with reinforced concrete. It is related precedent, but not the same assembly as TWT.
A comfort measure that considers both air temperature and the temperatures of surrounding surfaces.
Thermal energy exchanged between surfaces and people through infrared radiation. A radiant wall also exchanges heat through convection.
Thermal energy that changes a material's temperature without changing its state, such as warming or cooling concrete.
The ability of a material to absorb, store, and release sensible heat, moderating changes in temperature over time.
The intentional use of a material or medium to hold thermal energy for use at another time.
A path through an assembly that conducts heat more readily than the surrounding insulation, increasing heat loss or gain.
Source practice
A patent, a model, a laboratory test, and a measured building each answer different questions. The reliability of a conclusion depends on method, scope, and transparency.
Establishes ownership and novelty; it does not establish installed performance.
Tests a scenario under assumptions; it does not replace measurement.
Characterizes a representative assembly under controlled conditions.
Shows performance for an actual design, climate, operation, and period of observation.